Skip to main content

Table 1 System parameters

From: Optimization of CCGT power plant and performance analysis using MATLAB/Simulink with actual operational data

Symbol

Description

Value

T i

Compressor inlet temperature

30°C

T do

Compressor discharge temperature

390°C

T fo

Gas turbine inlet temperature

1085°C

T eo

Gas turbine exhaust temperature

535°C

P ro

Compressor pressure ratio

11.5

γ

Ratio of specific heat

1.4

η c

Compressor efficiency

0.85

η t

Turbine efficiency

0.85

R

Speed Regulation

0.04

T t

Temperature control integration rate

0.469

T c max

Temperature control upper limit

1.1

T c min

Temperature control lower limit

0

F d max

Fuel control upper limit

1.5

F d min

Fuel control lower limit

0

T v

Valve positioner time constant

0.05

T fu

Fuel system time constant

0.4

T w

Air control time constant

0.4669

T cd

Compressor volume time constant

0.2

K 0

Gas turbine output coefficient

0.0033

K 1

Steam turbine output coefficient

0.00043

T g

Governor time constant

0.05

K 4

Gain of radiation shield

0.8

K 5

Gain of radiation shield

0.2

T 3

Radiation shield time constant

15

T 4

Thermocouple time constant

2.5

T 5

Temperature control time constant

3.3

K 3

Ratio of fuel adjustment

0.77

K 6

Fuel valve lower limit

0.23

T m

Tube metal heat capacitance time constant of waste heat recovery boiler

5

T b

Boiler storage time constant of waste heat recovery boiler

20

T i

Turbine rotor time constant

18.5

W

Air flow

1.0