Skip to main content

Table 2 List of type, length, inner diameter (regarded as hydraulic diameter) and heat-load specification for each cryogenic piping element of the LHe supply line. Note that the vacuum-jacketed solid line of L1 includes two vertical bayonets; the multi-channel line of L1 includes one cryogenic value

From: Pressure drop of two-phase helium along long cryogenic flexible transfer lines to support a superconducting RF operation at its cryogenic test stand

Element

L1

L2

L3

L4

L5

L6

L7

L8

L9

L10

L11

L12

L13

Type

+

+

+

Horizontal bayonet

Horizontal bayonet

Horizontal bayonet

+

Size [ℓ (m), Dh (mm)]

(3.1,22.45)

(3.8,22.45)

(1.5,22.45)

(4,22.45)

(1,13.85)

(5,20.2)

(0.6,22.45)

(67,21)

(0.6,22.45)

(138,21)

(0.6,22.45)

(2.5,17.12)

(1,17.12)

(8,27.86)

Heat load (W)

8.95

1.14

6.1

1.2

1.4

7.5

4.75

4.02

4.75

8.28

4.75

3.5

1.4

14.6

  1. + vacuum-jacketed solid line; ■ multi-channel line; vacuum-jacketed flexible line; four-tube flexible coaxial line