Table 1 Operating conditions and ranges of the applied heater power for five test cases

From: Pressure drop of two-phase helium along long cryogenic flexible transfer lines to support a superconducting RF operation at its cryogenic test stand

Case

MD #1 average pressure (kPa)

S0 average pressure (kPa)

LHe valve at VB #1 (%)

CGHe valve at VB #1 (%)

S0 heater power (W)

1

145

126.33

86.0

90

30–70

2

145

127.66

86.0

90

30–80

3

145

127.04

86.0

90

40–85

4

150

127.70

98.5

100

40–100

5

150

129.08

98.0

100

50–100