From: Thermal–hydraulic analysis of the coil test facility for CFETR
Holding time (s) | A1 channel | B1 channel | ||
---|---|---|---|---|
Max. cable temperature (K) | Max. helium pressure (MPa) | Max. cable temperature (K) | Max. helium pressure (MPa) | |
2.0 (Ref.) | 78.9 | 4.18 | 76.6 | 1.66 |
2.5 | 85.0 | 4.19 | 83.9 | 1.70 |
3.0 | 91.6 | 4.22 | 92.0 | 1.75 |
3.5 | 98.7 | 4.24 | 101.0 | 1.81 |
4.0 | 106.4 | 4.27 | 111.1 | 1.90 |