Skip to main content

Table 3 Sensitivity of maximum cable temperature and maximum helium pressure to threshold voltage for the A1 and B1 channels

From: Thermal–hydraulic analysis of the coil test facility for CFETR

Threshold voltage (V)

A1 channel

B1 channel

Max. cable temperature (K)

Max. helium pressure (MPa)

Max. cable temperature (K)

Max. helium pressure (MPa)

0.3

74.3

4.18

68.3

1.65

0.4 (Ref.)

78.9

4.19

76.6

1.66

0.45

81.3

4.22

82.3

1.68

0.50

83.8

4.24

82.4

1.69