From: Thermal–hydraulic analysis of the coil test facility for CFETR
Threshold voltage (V) | A1 channel | B1 channel | ||
---|---|---|---|---|
Max. cable temperature (K) | Max. helium pressure (MPa) | Max. cable temperature (K) | Max. helium pressure (MPa) | |
0.3 | 74.3 | 4.18 | 68.3 | 1.65 |
0.4 (Ref.) | 78.9 | 4.19 | 76.6 | 1.66 |
0.45 | 81.3 | 4.22 | 82.3 | 1.68 |
0.50 | 83.8 | 4.24 | 82.4 | 1.69 |