From: The computation of confidence intervals for the state parameters of power systems
Estimated parameters | True values | Average LCL | Average UCL | Coverage Prob (%) |
---|---|---|---|---|
θ 02 | −3.70 | −4.82 | −3.26 | 97.12 |
θ 03 | −4.30 | −6.10 | −4.12 | 81.56 |
θ 04 | −4.20 | −5.29 | −4.10 | 89.56 |
θ 05 | −5.30 | −6.67 | −5.23 | 80.71 |
θ 06 | −5.90 | −7.68 | −5.11 | 60.67 |
V 01 | 241.50 | 238.86 | 245.72 | 98.12 |
V 02 | 241.50 | 238.22 | 244.54 | 98.54 |
V 03 | 246.10 | 242.57 | 249.26 | 99.10 |
V 04 | 227.60 | 224.04 | 231.18 | 98.07 |
V 05 | 226.70 | 223.06 | 230.11 | 96.23 |
V 06 | 231.00 | 227.23 | 234.36 | 97.44 |