From: Reliability of digital reactor protection system based on extenics
No | Downlink path | C (ms) | M (ms) | N (ms) | K c |
---|---|---|---|---|---|
1 | SCID → ESF → CIC-A3 | 252 | 200 | 500 | 0.83 |
2 | SCID → SRC → CIC-A3 | 214 | 200 | 500 | 0.95 |
3 | SCID → RPC | 198 | 200 | 500 | 0.99 |
4 | SCID → CCMS | 260 | 200 | 500 | 0.80 |
5 | SCID → SRC | 476 | 200 | 500 | 0.08 |