Skip to main content

Table 2 ESF response time

From: Reliability of digital reactor protection system based on extenics

No Condition C (ms) M (ms) N (ms) K c
1 Low-low pressurizer pressure 140.6 130 150 0.47
2 High differential pressure in steam line 138.3 130 150 0.59
3 High containment pressure (max 2) 142.1 130 150 0.40