From: Piecewise modelling and parameter estimation of repairable system failure rate
Number of failure | Total failure time (h) | Number of failure | Total failure time (h) | Number of failure | Total failure time (h) | Number of failure | Total failure time (h) |
---|---|---|---|---|---|---|---|
1 | 216 | 14 | 53,262 | 27 | 129,726 | 40 | 191,921 |
2 | 522 | 15 | 58,536 | 28 | 132,588 | 41 | 193,253 |
3 | 990 | 16 | 66,546 | 29 | 139,770 | 42 | 195,282 |
4 | 1368 | 17 | 68,310 | 30 | 145,314 | 43 | 197,686 |
5 | 4248 | 18 | 76,734 | 31 | 149,868 | 44 | 199,193 |
6 | 6354 | 19 | 80,406 | 32 | 153,054 | 45 | 199,901 |
7 | 10,728 | 20 | 85,842 | 33 | 162,036 | 46 | 200,671 |
8 | 17,046 | 21 | 95,400 | 34 | 168,666 | 47 | 201,244 |
9 | 23,652 | 22 | 97,578 | 35 | 174,137 | 48 | 201,739 |
10 | 29,862 | 23 | 107,010 | 36 | 179,169 | 49 | 202,810 |
11 | 35,730 | 24 | 111,492 | 37 | 183,413 | 50 | 202,978 |
12 | 39,276 | 25 | 116,892 | 38 | 186,045 | Type-I censored test time: ts = 203,115 | |
13 | 48,366 | 26 | 121,662 | 39 | 189,225 |