From: Performance analysis of electronic power transformer based on neuro-fuzzy controller
Parameters | Value |
---|---|
Grid voltage | 800 Vrms |
DC voltage of input stage | 2000 V |
DC voltage of isolation stage | 400 V |
Power frequency | 50 Hz |
Grid resistance and inductance | 0.1 Ω, 5 mH |
HF transformer | 5:1, 1000 Hz, 30 kVA |
Capacitors | 3.3 mF, 4.7 mF |