Table 5 Performance of breaker after optimization (55 lpm)

From: Case study on impact performance optimization of hydraulic breakers

 

Impact frequency (bpm)

Impact energy (J/blow)

Pulsation (Supply) (bar)

Pulsation (Return) (bar)

Current

750

540.59

46.26

33.66

OPT

870

573.25

34.62

31.21

Comparison (%)

16

6.04

−25.16

−7.28