Table 3 Breaker performance upon variation of high-sensitivity variables (valve)

From: Case study on impact performance optimization of hydraulic breakers

Parameter

Result

Min

Max

Vdia2

Impact frequency (bpm)

540

540

Impact energy (J/blow)

514.46

514.98

Pulsation (Supply) (bar)

62.50

62.67

Pulsation (Return) (bar)

28.42

28.47

Vdia3

Impact frequency (bpm)

510

540

Impact energy (J/blow)

514.42

514.71

Pulsation (Supply) (bar)

67.83

70.85

Pulsation (Return) (bar)

17.39

30.52

Vlap1

Impact frequency (bpm)

570

540

Impact energy (J/blow)

517.08

510.14

Pulsation (Supply) (bar)

75.35

68.42

Pulsation (Return) (bar)

29.13

21.24

Vlap2

Impact frequency (bpm)

540

540

Impact energy (J/blow)

514.00

515.32

Pulsation (Supply) (bar)

80.00

72.48

Pulsation (Return) (bar)

22.98

31.49

Vhl

Impact frequency (bpm)

540

540

Impact energy (J/blow)

514.60

514.60

Pulsation (Supply) (bar)

62.86

62.28

Pulsation (Return) (bar)

28.13

28.69