Table 2 Synchronous machine parameters

From: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

Parameter

Value (per unit)

Time constant

Value (sec)

\({\text{X}}_{\text{a}}\)

0.130

\({\text{T}}_{{{\text{d}}0}}^{ '}\)

4.3

\({\text{X}}_{\text{d}}\)

1.79

\({\text{T}}_{{{\text{d}}0}}^{''}\)

0.032

\({\text{X}}_{\text{d}}^{ '}\)

0.169

\({\text{T}}_{{{\text{q}}0}}^{ '}\)

0.85

\({\text{X}}_{\text{d}}^{''}\)

0.135

\({\text{T}}_{{{\text{q}}0}}^{''}\)

0.05

\({\text{X}}_{\text{q}}\)

1.71

  

\({\text{X}}_{\text{q}}^{ '}\)

0.228

  

\({\text{X}}_{\text{q}}^{''}\)

0.200