Skip to main content

Advertisement

Table 1 Summary of vibration guide values for structure damage

From: Dynamic effect of metro-induced vibration on the rammed earth base of the Bell Tower

Vibration standard Evaluating index Evaluation object Evaluation value (mm/s)
ISO 4866:2010 (ISO 2010) PPV Ancient architecture 2.5
Germany DIN4150-3:1999 (Germany 1999) PPV Ancient architecture 3–10
UK BS7385-2 (UK 1993) PPV Ancient architecture 7.5
Switzerland 6.10SN640312:1992 (Swiss 1992) PPV Old and poorly maintained buildings 2
Portugal (Meng 2009) PPV Ancient architecture 2.5
Japan (Cao 2006) PPV Ancient architecture 5
China GB10070-88 (China 2003) PPV Ancient architecture (cracking and weathering) 1.8–3.0
China GB/T50452:2008 (China 2008) PPV Ancient architecture 3–5
State Administration of Cultural Heritage (Meng 2009) PPV The Bell Tower and the City Wall 0.15–0.2