Table 3 Nuclear data of resonance monitors used for the α-parameter measurement

From: Measurement of neutron energy spectrum at the radial channel No. 4 of the Dalat reactor

Monitor

reaction

M

θ (%)

σ0 (barn)

I0 (barn)

\(\left\langle {{\text{E}}_{\text{r}} } \right\rangle\) (De Corte et al. 1981) (eV)

T1/2

Eγ (keV)

γ (%)

Au

197Au(n, γ)198Au

196.97

100

98.7

1563.56

5.47

2.697 d

411.8

95.53

In

115In(n, γ)116mIn

114.82

95.7

164.3

2600

1.45

54.2 m

416.9

30.0

Mn

55Mn(n, γ)56Mn

54.98

100

13.4

11.76

337.1

2.582 h

847

99.99