Skip to main content

Table 2 Comparison of present results on mixing index with those of previous studies

From: Parametric investigation on mixing in a micromixer with two-layer crossing channels

Sr. no

Investigators

Geometrical shapes

Design parameter

Hydraulic Dia. (mm)

Reynolds number

Mixing length (mm)

Mixing index (Mo) variations in the tested range

1

Ansari and Kim (2009)

3D serpentine

straight channel length to the channel width (s/d)

0.15

1.0

12

0.23–0.25

2

Hossain and Kim (2014)

Unbalanced three split and recombine

rhombic angle (θ)

0.15

0.1

4.0

0.23–0.31

3

Hossain and Kim (2015)

3D serpentine split and recombine

sub-channel width to the main channel width (w/W)

0.13

0.1

2.1

0.42–0.43

4

Alam and Kim (2012)

Curved microchannel with rectangular grooves

groove depth to the main channel width (d/W)

0.1

0.5

2.66

0.20–0.21

5

Present study

Two-layer crossing microchannels

channels depth to the main channel width (D/H)

0.2

0.2

7.2

0.89–0.99