From: POD analysis of flow over a backward-facing step forced by right-angle-shaped plasma actuator
Snapshots N | \(\left\langle {{{u}}^{{\prime }} {{u}}^{{\prime }} } \right\rangle / {{U}}_{\infty }^{ 2} { \times 100}\) | \(\left\langle {{{v}}^{{\prime }} {{v}}^{{\prime }} } \right\rangle / {{U}}_{\infty }^{ 2} { \times 100}\) | \({ - }\left\langle {{{u}}^{{\prime }} {{v}}^{{\prime }} } \right\rangle / {{U}}_{\infty }^{ 2} { \times 100}\) |
---|---|---|---|
100 | 1.063 | 0.435 | 0.441 |
150 | 1.197 | 0.526 | 0.462 |
170 | 1.172 | 0.526 | 0.453 |
175 | 1.168 | 0.528 | 0.446 |
180 | 1.171 | 0.5287 | 0.45 |
190 | 1.173 | 0.5294 | 0.451 |
200 | 1.176 | 0.53 | 0.45 |
Hot-wire | 1.14 | 0.5057 | 0.48188 |