Skip to main content

Table 2 Comparision of target coverage metrics for the PTV as a function of plan modality (\(\overline{x}\) ± SD)

From: The choice of multi-beam IMRT for whole breast radiotherapy in early-stage right breast cancer

Metric

3DCRT

for-IMRT

inv-IMRT

HT

VMAT

p-value

Dmax (Gy)

55.94 ± 1.34

55.01 ± 1.30

54.16 ± 0.54

53.85 ± 0.66

55.08 ± 0.72

<0.001

Dmean (Gy)

51.86 ± 1.04

51.66 ± 1.00

51.18 ± 0.36

50.85 ± 0.22

51.35 ± 0.40

0.019

V53.5 (%)

20.56 ± 15.60

13.03 ± 12.80

1.85 ± 1.77

0.39 ± 0.59

10.15 ± 2.98

<0.001

IB-V50Gy (cc)

765 ± 338

659 ± 423

696 ± 314

750 ± 376

717 ± 399

0.964

OB-V50Gy (cc)

379 ± 323

245 ± 239

103 ± 58

76 ± 51

57 ± 29

<0.001

CN

0.58 ± 0.07

0.62 ± 0.08

0.75 ± 0.05

0.80 ± 0.05

0.73 ± 0.06

<0.001

HI

0.13 ± 0.02

0.12 ± 0.07

0.09 ± 0.01

0.06 ± 0.01

0.17 ± 0.02

<0.001

MU

231 ± 29 MU

222 ± 14 MU

1245 ± 146 MU

9284 ± 354 MU

300 ± 52 MU

<0.001

  1. D max max dose, D mean mean dose, V x volume (%) receiving x dose (Gy) or higher, IB-V 50Gy prescribed dose volume (cc) inside of the PTV, OB-V 50Gy prescribed dose volume (cc) outside of the PTV, \(\overline{x}\) mean dose, SD standard deviation, CN conformation number, HI homogeneity index, MU monitor unit