Skip to main content

Table 6 Obtained results for Jouve3 (with DWT)

From: Comparison study of EMG signals compression by methods transform using vector quantization, SPIHT and arithmetic coding

CF (%)

PRD (%)

SNR (dB)

86.13

0.4

47.85

79.98

0.18

54.61

73.82

0.10

59.72

67.48

0.052

65.62

61.18

0.027

71.27

54.88

0.013

77.41

48.58

0.0069

83.16

42.23

0.0034

89.13

35.93

0.0016

95.45

10.79

0.0001

119.57