Skip to main content

Table 3 Experimental results

From: A performance comparison of static VAr compensator based on Goertzel and FFT algorithm and experimental validation

 

Goertzel algorithm

FFT algorithm

Loads: 300 W + 200 VAr

Before compensation

 V

207.81

207.20

 A

1.680

1.690

 VA

349.12

350.18

 W

288.85

288.02

 VAr

197.41

196.84

 P.F.

0.82

0.82

After compensation

 V

207.81

207.20

 A

1.390

1.400

 VA

288.85

290.09

 W

286.77

285.94

 VAr

33.24

35.22

 P.F.

0.99

0.99

 Computation time

0.06

0.085