Skip to main content

Table 1 Open loop eigenvalues

From: Optimal design of proportional–integral controllers for stand-alone solid oxide fuel cell power plant using differential evolution algorithm

Eigenvalues Associated states Participation factor (%)
−0.0171 T e 100
0.0383 \(\Delta P_{{h_{2} }}\) 100
0.3436 \(\Delta P_{{o_{2} }}\) 100
−0.0128 \(\Delta P_{{h_{2} o}}\) 100
−0.2 I fc 100