From: A preliminary study on improving the recognition of esophageal speech using a hybrid system based on statistical voice conversion
39 monophone HMMs with 16 Gaussians per state \(+\) Bigram
Accuracy (%)
Correct (%)
Exp 1 : \(39 \ MFCC\) coefficients
69.19
71.78
Exp 2 : \(52 \ MFCC\) coefficients
67.96
71.38
Exp 3 : \(HLDA \ (52\rightarrow 39)\)
71.32
74.07