From: QoS-based management of biomedical wireless sensor networks for patient monitoring
Network: | |
---|---|
Deployment Area | 80 m × 80 m |
Deployment Type | 5 × 5 grid (see Figure 4) |
Number of Nodes | 1 sink and 25 sensor nodes |
Sink Position | (40,40) m |
Radio Range | 30 m |
Radio Model | Unit Disk Graph Medium Distance Loss |
Setup Time | 60 s |
Network Layer | IPv6 with 6LowPAN |
Transport Layer | User Datagram Protocol (UDP) ([Postel 1980]) |
Routing Protocol | RPL with the MRHOF ([Gnawali and Levis 2012]) |
Logical Topology | Random |
PRR Required | 98%,91% |
Application: | |
Task Type | Time driven |
Data Length | < 70 bytes (one packet) |
Reporting Interval (s) | 1, 2 |
Simulation: | |
Time | 1000 s |