Skip to main content

Table 2 Variation of the calculated thermal neutron flux, in cm -2s -1 th ), and the factor f th epi ) in the inclined tube of TRIGA’s reactor with the vertical distance Z from the core

From: Proposed design for the PGAA facility at the TRIGA IPR-R1 research reactor

Z(cm)

86

178

270

361

451

541

631

721

811

ϕth

4.7 x109

1.1 x108

2.1 x107

9.5 x106

5.5 x106

2.9 x106

1.9 x106

1.4 x106

1.0 x106

Δcod.(%)

5

10

2

3

2

3

2

2

2

f

42

25

17

16

17

20

13

13

13