Skip to main content

Table 1 %THD & switching angles in degrees at various M I

From: Harmonic analysis and FPGA implementation of SHE controlled three phase CHB 11-level inverter in MV drives using deterministic and stochastic optimization techniques

S. no

MI

α1

α2

α3

α4

α5

%THD

1.

0.460

35.46

47.39

59.32

73.95

88.73

8.81

2.

0.473

35.33

46.87

58.47

72.40

87.68

8.62

3

0.485

35.33

46.32

57.82

70.96

86.56

8.98

4

0.495

35.44

45.78

57.39

69.77

85.49

8.88

5

0.500

35.52

45.49

57.20

69.20

84.92

8.77

6

0.555

33.75

44.94

53.54

65.22

77.14

7.60

7

0.600

26.64

43.93

51.53

62.39

72.50

7.24

8

0.655

18.98

34.82

51.33

57.94

69.32

6.32

9

0.750

12.79

21.01

35.81

56.59

61.31

5.63

10

0.755

11.66

20.93

34.83

54.41

62.67

5.33

11

0.800

6.569

18.94

27.18

45.13

62.24

5.55