Table 6 The system is compensated so that the 4th natural frequency is held constant

From: Can a brace be used to control the frequencies of a plate?

Young’s modulus

Brace thickness

1st natural frequency

% change of ω 1 from

4th natural frequency

% change of ω 4 from

E R (MPa)

h b (m)

ω 1 (Hz)

E R  = 850

ω 4 (Hz)

E R  = 850

600

0.0909

934

58%

1015

0.0%

650

0.0683

927

57%

1015

0.0%

700

0.0387

907

54%

1015

0.0%

750

0.0194

781

32%

1015

0.0%

800

0.0144

661

12%

1015

0.0%

850

0.0120

590

0%

1015

0%

900

0.0104

541

8%

1015

0.0%

950

0.0093

508

14%

1015

0.0%

1000

0.0084

482

18%

1014

0.1%

1050

0.0077

462

22%

1014

0.1%

1100

0.0071

446

24%

1014

0.1%